Water and particles had contaminated the oil at Commonwealth Steel. HIPPO filtration brought both below the site's targets, allowing the existing oil to stay in service.

Steel manufacturing
Hydraulic oil
Glowing steel moving through industrial rolling equipment
Steel production image from Filtertechnik's case document.
800 → 50Water content, ppm
13/12/8Final ISO cleanliness code
2 daysReported cleanup time

01 / The challenge

The installed filter wasn't achieving the required oil condition.

Commonwealth Steel produces grinding media for mining. Its hydraulic oil contained both solid particles and water. The initial condition was ISO 21/19/16 with 800 parts per million of water, despite an existing 25 µm nominal filter.

The site wanted particle cleanliness below ISO 15/13/10 and water below 80 ppm. Approximately 900 litres of ISO VG 32 oil needed treatment. The immediate question was whether filtration could restore the oil to the required cleanliness without a complete oil replacement.

02 / The approach

Verify the contamination. Treat the existing oil.

  1. Confirm the starting condition

    Filtertechnik's case document describes checking the laboratory findings with a portable Particle Pal. The field check confirmed similar contamination levels.

  2. Circulate through two HIPPO filters

    PT Kelmer arranged two HIPPO pots in parallel on a portable external circulation loop. The partner's web account gives a flow rate of 520 litres per hour.

  3. Check the result and continue filtration

    The reported readings met both site targets. Filtertechnik's case document says the customer retained the oil and installed continuous filtration after the cleanup.

03 / The results

Less water. Fewer particles.

Filtertechnik reports the following results. Its supporting web case gives a treatment duration of two days.

Before
800 ppm
After
50 ppm
Reported oil condition before and after treatment, compared with the customer's targets
MeasurementBeforeSite targetAfter
Water, ppm800Below 8050
ISO cleanliness21/19/16Below 15/13/1013/12/8

04 / Applying the findings

Start with the oil condition, then choose the treatment.

This case shows a documented cleanup of particle and water contamination. It gives another plant a useful basis for discussing treatment, but the final readings do not set an acceptance limit for every hydraulic system.