NATCOM
Hydraulic press valve sticking

Stopping valve sticking on automotive presses

Varnish kept interfering with valve movement on an automaker's steel presses. Adding oil testing and targeted deposit treatment stopped the sticking and the production delays it caused.

Hydraulic presses
Valve sticking
Deposit treatment
Yellow industrial robots handling vehicle body panels on an automotive assembly line
In automotive manufacturing, a sticking press valve can delay the next production step.
Valve sticking stoppedLower varnish potentialReported oil saving: 2,000 gallons

01 / The challenge

The valves kept sticking. The oil condition was going unchecked.

A major automobile manufacturer was losing production time when the valves on its hydraulic steel presses stuck. Varnish had accumulated in the systems, and the absence of oil testing meant the problem repeatedly caught the maintenance team by surprise. Pump failures and seal locking added to the maintenance burden.

Existing varnish removal equipment consumed large numbers of filter elements. Once the equipment was disconnected, varnish-potential readings rose again. The team needed a way to control deposits and follow the oil condition before valve movement disrupted production.

02 / The approach

Combine deposit treatment with oil condition checks.

  1. Make varnish potential visible

    The team added membrane patch colorimetry, or MPC, to its condition monitoring program. MPC measures varnish potential in oil, giving the team a way to follow the deposit problem through treatment.

  2. Treat deposits in the hydraulic system

    Fluitec DECON™ was added at a 3% concentration for this application. Varnish levels began to decline steadily, and the valves stopped sticking.

  3. Support continued deposit control

    DECON™ AW was also added to help maintain antioxidant levels and control further deposit formation. The approach addressed the condition of the hydraulic oil alongside the immediate valve problem.

03 / The outcome

The valves stopped sticking and the oil condition improved.

The treatment stopped the sticking valves and the production delays they caused. MPC results declined, while RULER results, which track antioxidant levels, increased. Fluitec describes the system as free of varnish after treatment and reports an oil saving of 2,000 gallons, or 7,570 litres.

Valve operation
Sticking stopped
Production
Delays caused by sticking valves eliminated
Oil condition
MPC declined; RULER values increased
Reported oil saving
2,000 gallons / 7,570 litres

04 / Applying the findings

Follow the valve behaviour and the oil together.

Recurring valve sticking gives the maintenance team a reason to examine the fluid as well as the component. Record when sticking occurs, which valves are affected and what changes after maintenance. Pair that history with oil analysis that addresses varnish potential and lubricant condition.

The next decision is which treatment fits the actual problem. Hydraulic oil filtration addresses contamination; deposit treatment and additive replenishment require a review of the lubricant, equipment requirements and test results. After treatment, follow both the oil trend and the return of reliable valve movement.

Our guide to hydraulic oil varnish and sticking servo valves explains how deposits affect press response and what to check before replacing another valve.

Find out why your press valves keep sticking

Send the lubricant details, recent oil results, valve replacement history and the conditions when sticking occurs. NATCOM can assess the oil condition and the treatment or testing needed.